Product Details:
|
|
Place of Origin: | China |
---|---|
Brand Name: | HENGFENGYOU |
Certification: | ISO IEC CB COC KEMA SNI SABS CCC |
Model Number: | sz9 |
Payment & Shipping Terms:
|
|
Minimum Order Quantity: | 1 |
Price: | 500-30000 |
Packaging Details: | wooden case |
Delivery Time: | 15 DAYS |
Payment Terms: | LC T/T |
Supply Ability: | 5000 pieces/year |
Detail Information |
|||
Usage: | Electronic | Model Number: | Sz9 |
---|---|---|---|
Phase: | Three | Standard: | GB1094-1996 |
Application: | Electric | Material: | Copper Winding |
Keywords: | Distribution Power Transformer | Rated Voltage: | 800 ~ 31500kva |
Vector Group:: | Dyn11,Dyn5,Yyno Or Others | CORPORATION::: | KPLC/REA/PEC |
Phase:: | Single Or Three Phase | CERTIFICATION:: | Type Test Report/CESI/ CTQC |
High Light: | three phase oil immersed transformer,oil immersed distribution transformer |
Product Description
35kv class 800 ~ 31500kva three-phase double-winding on-load voltage regulating
oil-immersed power transformer
Hengfengyou oil-immersed power transformer is the latest product designed and developed on the
basis of absorbing the most advanced technology at home and abroad. It has high reliability, low
partial discharge, low noise, low loss and high anti-short circuit ability. Its excellent and reliable
performance has won customers as well as the reorganization of experts and appreciation
Rate Power (KVA) |
VoltageCombination(kV) | Connection Symbol |
Losses(kW) | No-load current (%) |
Impedance voltage (%) |
Weight(kg) | Dimension(mm) | Gauge (mm) |
|||||||
HV (KV) |
Tapping rangeof H.V.(%) |
LV (kV) |
|No-load loss |
Load loss |
Core | Oil | Total | L | W | H | |||||
30 | 30 33 35 |
+5% +2*2.5% |
0.4 | Yd11 | 0.11 | 0.83/0.79 | 2.2 | 6.5 | 195 | 260 | 665 | 1140 | 775 | 1725 | 550 |
50 | 0.17 | 1.21/1.15 | 2 | 275 | |305 | 805 | 1170 | 935 | 1740 | 550 | |||||
100 | 0.23 | 2.01/1.9 | 21.7 | 405 | 380 | 1150 | 1230 | 940 | 1820 | 550 | |||||
125 | 0.27 | 2.38/2.26 | 1.8 | 525 | 410 | 1285 | 1335 | 960 | 1890 | 550 | |||||
160 | 0.29 | 2.82/2.69 | 1.6 | 610 | |440 | 1335 | 1360 | 980 | 1910 | 660 | |||||
200 | 0.34 | 3.33/3.16 | 1.5 | 720 | 465 | 1490 | 1385 | 1020 | 1945 | 660 | |||||
250 | 0.41 | 3.95/3.7 | 61.4 | 815 | 490 | 1635 | 1410 | 1050 | 2010 | 660 | |||||
315 | 0.49 | 4.76/4.5 | 31.4 | 930 | 520 | |1765 | 1440 | 1100 | 2060 | 660 | |||||
400 | 0.58 | 5.75/5.47 | 1.3 | 1205 | 610 | 2050 | 1560 | 1130 | 2120 | 820 | |||||
500 | 0.69 | 6.92/6.5 | 81.2 | 1340 | 680 | |2200 | 1690 | 1150 | 2200 | 820 | |||||
630 | 0.83 | 7.87 | 1.1 | 1575 | 725 | 2565 | 1800 | 1180 | 2235 | 820 | |||||
800 | 0.98 | 9.41 | 1 | 1895 | 890 | 2950 | 1940 | 1200 | 2250 | 820 | |||||
1000 | 1.15 | 11.54 | 1 | 2145 | 1005 | 3650 | 2080 | 1230 | 2315 | 820 | |||||
1250 | 1.41 | 13.97 | 0.9 | 2455 | 1160 | 3810 | 2140 | 1270 | 2360 | 820 | |||||
1600 | 1.7 | 16.67 | 0.8 | 2730 | 1250 | 4520 | 2360 | 1310 | 2400 | 820 | |||||
2000 | 2.01 | 19.71 | 0.8 | 3040 | 1310 | 5200 | 2400 | 1350 | 2515 | 820 | |||||
2500 | 2.37 | 23.3 | 0.7 | 3450 | 1690 | 6300 | 2490 | 1480 | 2690 | 820 | |||||
3150 | 2.82 | 27.71 | 0.6 | 4100 | 2050 | 8350 | 2555 | 1560 | 2730 | 820 | |||||
4000 | 3.37 | 33.15 | 0.6 | 5050 | 2670 | 9550 | 2675 | 1600 | 2810 | 1070 |
1.
Low partial discharge: the apparent discharge quantity is usually less than 100pC;
2.
Low noise: Product of 63MVA or below 63MVA has a noise level less than 60dB;
3.
Low loss: no-load loss is reduced by 20 percent compared with that specified in national standards;
4.
High anti-short capability: the SFZ10-40000/110 transformer has passed the short-circuit test carried out by China National Transformer Quality Supervision Testing Center.
The interleaved and continuous winding structure is adopted for HV windings, thus to improve
the electric distribution and effectively improve the anti-lightning impulse capability. Inner and
outer support strip structure is adopted. The support strips and pads are all rounded to improve
insulation reliability. Oil-directing structure is adopted in the winding, thus to reduce the hotspot
temperature and prolong insulation life.
Both the H.V and M.V. windings are usually provided with separate voltage regulating windings,
so the ampere-turn of all the windings are completely balanced. These can effectively eliminate
the axial electrodynamics force during external short circuit and improve the dynamic stability
under external short circuit.
1. Your inquiry related to our product & price will be replied within 48 hours
2. Well-trained & experienced staff are to answer all your inquiries in English
3. Working time: 8:00am ~17:30pm, Monday to Saturday. (UTC+8)
4. Customized solution & perfect after-sale service
5. Payment: we can accept T/T, L/C, Western Union.
6. For large order, engineer can be sent to your country for on-site mainternace instructions.
Enter Your Message